The ruling
It can, so clean them the makers' way: a garden hose and something soft, and nobody standing on the panels. REC says pressure cleaners will invalidate its warranty. Trina, Canadian Solar and LONGi cap the water at 40 bar or less, and Kärcher's K 5 home pressure washer is rated to about 159 bar.
The one maker that says it outright
REC is plain about it. Its cleaning guide says: "The use of pressure or steam cleaners and high pressure hoses, knives, blades and metallic sponges is not permitted on REC panels and will invalidate the warranty."1 It explains why: high pressure hoses "may exert pressure in excess of the certified load and cause impact damage, damage to the frame bonding, the laminate or cells and force water between the glass and frame."1 REC's current installation manual repeats the ban: "Use of high pressure hoses or cleaners is not permitted as these may damage the panels, laminate or cells."2
What REC allows instead is a garden hose: "A standard flexible garden hose with domestic water pressure may be used to apply as much water to the panel or array as necessary."1
In plain terms It is a "hand wash only" label, written into the warranty. On REC panels, a pressure washer is a written warranty problem, not a grey area.
The rest set a limit, and exclude cleaning damage
Most other makers allow a rinse under pressure up to a ceiling, and put damage from cleaning against the manual outside their cover.
| Maker | What the manual allows | What it says about cleaning damage |
|---|---|---|
| Trina | Compressed water, "recommended maximum water pressure is 4 MPa (40 bar)" | "Damages caused by failure to clean or improper cleaning procedures will void Trina Solar warranty." |
| Canadian Solar (Australian manual) | Wet cleaning at "a maximum water pressure not exceeding 4 MPa (40 bar)" | "Damages induced by inappropriate cleaning procedures will void Canadian Solar warranty." |
| LONGi | Pressure water on the module surface "shall not exceed 0.7Mpa" (7 bar) | Do not use steam or corrosive chemicals |
| Risen | Water pressure on the glass "must not exceed 4 MPa" | If the glass is "damaged due to any external force, the Risen Energy warranty will be voided" |
| AIKO | High pressure water cleaning, "Recommended maximum water pressure is 4MPa(40bar)" | No acid or alkali detergents, no rough tools |
| SunPower (Australian manual) | "up to 100 bar at ≥50 cm distance" | Harsh materials "or cleaning without consultation will invalidate the product warranty" |
Sources: Trina3, Canadian Solar4, LONGi5, Risen6, AIKO7, SunPower8. Tindo, the Australian maker, says to rinse panels with water and to clean the glass "only with soft cloth using warm water or ethanol".9
Now put a home pressure washer next to those numbers. Kärcher's K 5 Premium home model is rated to a maximum of 2,300 psi, about 159 bar.10 That is past every limit in the table: around four times the 40 bar that Trina, Canadian Solar, Risen and AIKO allow, more than twenty times LONGi's 7 bar, and more than half as much again as SunPower's 100.
In plain terms The makers set a speed limit, and a home pressure washer drives straight past it. The damage it does on the way falls outside their cover.
Keep the glass clear, the makers' way
The same makers that cap the water pressure also count neglect against the warranty. Trina puts the two in one sentence: "failure to clean or improper cleaning procedures will void Trina Solar warranty."3 Canadian Solar, on shading: "If a defect (such as a hot spot) is caused due to a panel being improperly installed in the shade or due to poor maintenance, it will void Canadian Solar's warranty."4
Shade is how growth does the damage. Canadian Solar says power dissipated in fully or partially shaded cells "will result in power loss, reduced yield and can cause localized overheating".4 LONGi says "partial obstruction may even cause hot spots. Therefore, modules need to be cleaned regularly", and that long term shading damages the module and its cells.5 A crust of lichen on the glass is partial obstruction that stays put.
In plain terms A shaded cell is a kink in a hose. The rest of the panel keeps pushing, and the pressure shows up at the kink, as heat.
So growth on panels has to come off, and come off the makers' way: water and something soft. SunPower says a soft sponge or cloth8; REC says a soft sponge, microfibre cloth or non-abrasive brush.1 How lichen settles on the glass, and where, is in lichen on solar panels.
What an installer says
Solargain, a Perth solar installer, tells its customers the same thing the makers do: "High pressure washers can be very detrimental to the operation of your panels, as they risk causing microfractures in the glass of the panel. You also risk voiding your warranty by using a pressure washer, as many stipulate that this should not be done."11 Its advice is a normal hose for the panels, and to leave climbing onto the roof to professionals.
In plain terms The people who bolt the panels to your roof and the people who make them say it the same way. Hose, yes. Pressure washer, no.
Never stand on the panels
On this the makers agree completely. Trina: "Do not stand on the module glass while working."3 Canadian Solar: "Do not stand, step, walk, and/or jump on modules under any circumstances," because localised heavy loads "may cause severe micro-cracks at the cell level, which in turn may compromise module reliability and void Canadian Solar's warranty."4 REC: "Do not stand or walk on the panels."2 REC's cleaning guide says why: "Never at any point stand on, walk on, lean on or apply pressure to the panels as this can cause both visible and non-visible damage to the panel."1
Cleaning panels on a roof usually means getting up among them, and that is where most of the risk sits. The Western Australian government's own advice is that "The solar system should be shut down before anyone accesses the rooftop, gutters or the solar panels."12
In plain terms A micro-crack is a stone chip in a windscreen that nobody has spotted yet. It does not show from the ground, and a boot on the glass can cost a panel without anyone noticing on the day.
What this means for your roof
Lichen and moss on a roof with solar panels are a roof problem first, and the fix belongs on the roof. We treat them with UNGROW Bailiff from the roofline, from ladders, with a low pressure soft wash pump through non-directional nozzles, so nobody stands on a panel and no pressure washer goes anywhere near one. We spray around the panels, not on them, because REC says it "does not provide warranty for the application of any sprays or treatment".1
Also asked
Can I clean my solar panels with a garden hose?
Yes. REC, the strictest maker on pressure, says a standard garden hose at domestic water pressure may be used to apply as much water to the panels as necessary. SunPower says normal water pressure is sufficient. REC also says to clean while the panels are cool, early in the morning, because cold water on hot glass can crack it.
Which panels do I have?
The brand and model are on a label on the back of each panel, and usually on the installer's paperwork or system handover documents. The installation manual for that model is the document that sets the cleaning rules. Manuals change between models and years, so the one that counts is the version for the panels on your roof, from the year they were sold.
Does lichen on the panels affect the warranty?
Not when it is cleaned off the makers' way: water and something soft, no scrapers or harsh chemicals, and no home pressure washer, because Kärcher's K 5 is rated past every pressure limit in their manuals. Left on, it can: Trina says "Damages caused by failure to clean or improper cleaning procedures will void Trina Solar warranty", and Canadian Solar says a defect such as a hot spot caused "due to poor maintenance" will void its warranty. Growth that shades cells can cause hot spots.
Will a roof treatment affect my panels?
We keep UNGROW Bailiff, our roof treatment, off them. It goes on from the roofline through a low pressure soft wash pump and non-directional nozzles, and we spray around the panels, not on them. REC says it does not provide warranty for any sprays or treatments applied to its panels, so a roof treatment belongs on the roof, not on the glass or the frames.
On the record
- REC, Quick guide to cleaning
- REC, REC Alpha Pure Panels Installation Manual (Rev 18) (2026)
- Trina Solar, User Manual, Vertex Series Modules (UM-M-0002 PP7) (2026)
- Canadian Solar (CSI Solar), Installation Manual of Photovoltaic Module (AU), Rev 3.4 (2026)
- LONGi, PV Module Operation and Maintenance Manual (version 02) (2024)
- Risen Energy, Risen PV Module Installation and Maintenance Manual (A1, 2026) (2026)
- AIKO, AIKO PV Modules Installation Manual (V29) (2026)
- TCL SunPower, SunPower Performance and MAX Photovoltaic Modules Safety and Installation Instructions for Australia (Rev AJ) (2026)
- Tindo Solar, Installation Manual, Walara G4P Series PV Modules (Version 1.3) (2025)
- Kärcher Australia, Pressure washer K 5 Premium Power Control Home
- Solargain, The Do’s and Don’ts of panel maintenance (2022)
- Government of Western Australia, Electrical safety at home: solar PV systems